Unclogging a SimpleHuman Soap Dispenser

by scrope in Living > Kitchen

77300 Views, 12 Favorites, 0 Comments

Unclogging a SimpleHuman Soap Dispenser

20161228_0001.jpg

The SimpleHuman automatic soap dispenser is a touch-free pump that puts soap or sanitizer in your hand when you place it under the sensor. These are great in dispensing soap without having to touch anything but over time the soap can dry out (or if you use too thick a soap) and form a blockage in the tube leading from the pump to the dispenser port.

If this happens, the pump will whine but not dispense any soap. Sometimes you can flush it with water or thinner soap but if the blockage is too thick the only way to fix the problem is to disassemble the pump and remove the blockage.

Backflush the Soap Feed

IMG_5946.jpg
IMG_5945.jpg

I learned a new way of clearing soap blockages if they aren't too big. That means you don't have to completely disassemble the pump. It only takes a minute so it's an easy step to try.

Fill a SmartWater Sports bottle with hot water and place the blue nozzle to cover the output of the pump. Press the bottle to force the water down the tube and force any clog back into the reservoir.

  1. There is a lot of pressure when you squeeze the bottle so if you loose the connection with the soap dispenser you will squirt hot water all over the place. Don't ask me how I know this.
  2. The SmartWater Sports bottle has a nozzle you drink from that's the perfect size for covering the soap output feeder. It's also perfect for backflushing a Sawyer Mini Filter.
  3. You can use any other mechanism that allows you to force water back through the feed tube with sufficient pressure to dislodge a clog.

Remove 3 Screws

20161228_0002.jpg

The bottom is held on by three screws: the battery compartment screw (which is the one you normally use to replace the batteries) and two pump compartment screws.

Remove the Bottom

20161228_0003.jpg
20161228_0007.jpg

Remove the bottom of the dispenser.

The dial has a small cross bar that fits into the slot in the potentiometer. Note the location of the slot and the potentiometer. If you accidentally change either of them your pump will have different settings and you will need to open it up and adjust it. Also, when you try to put the bottom back on, you will need to ensure the bar and the slot are in alignment or you won't be able to attach the bottom.

I had already removed the pully before I took the photo.

Remove the Pully and the Pump

20161228_0004.jpg

Remove the pully from the motor and the pump.

Unscrew the 4 small screws that hold the pump to the assembly. The pump is not symmetrical so it needs to go back in the same way but it really only fits one way.

Unhook the pump from the flexible plastic tube. The tube feeds the port at the top of the dispenser.

Remove the Electronic Board

20161228_0005.jpg
20161228_0006.jpg

To get easier access to the pump tube, remove the two screws holding the electronic board and base. The board should just pull out.

Clean the Tube

This is what we've been waiting for and is the most difficult step. You need to clean out the hardened (or thickened) soap that's clogging the tube.

What I found worked best was a long and thin plastic rod that I had (a Camelbak cleaning rod -- just the rod, not the brush). Camelbak has changed their cleaning kits so unless you have an older one what you need is something long but tiny that will fit down the tube and break up the soap.

Also what worked especially well once I broke up some of the soap clogs was a Sawyer Mini cleaning plunger (syringe). It's the perfect size for the tube and allows you to force the water through it. You might try a SmartWater bottle with the sports cap but it may be too big for the tube.

Marvel at the Pump

20161228_0009.jpg
20161228_0010.jpg

The pump is pretty interesting and should be fine but it's interesting to see how it's constructed. What you see in the photos is the pump face that fits on the bottom of the soap reservoir and is fed from the tiny hole in the top.

The top of the pump is not glued and is just resting on the pump. I discovered this when it accidentally fell off.

Reassemble the Pump

20161228_0008.jpg

Put everything back together and you're done.

Remember to align the dial and potentiometer.

If you want to check to see if you've fixed the pump before putting it all back together, note that you can put the battery compartment back on without the bottom (but you will need to remove it when you attach the bottom).

I had some problem testing the pump with just water but once I put soap in the dispenser it started working just fine.